Autoclaves require chemically pure feedwater to sterilise instruments effectively and protect equipment from corrosion. AS 5369:2023 Table 7.4 sets strict chemistry and metals limits for dedicated steam generator feedwater — stricter in several parameters than the washer-disinfector requirements.
This test covers one sample from your autoclave feedwater supply point. Your kit includes pre-labelled sample bottles, step-by-step collection instructions, and a priority courier number for same-day collection. Results are emailed as a NATA-accredited Certificate of Analysis benchmarked against all AS 5369:2023 Table 7.4 limits.
What this test covers: pH · Conductivity · Total Hardness · Chloride · Total Solids (evaporative residue) · Reactive Silica · Reactive Phosphorus · Full heavy metals screen (Cd, Pb, As, Hg + others) · Colour and appearance
All parameters reported against AS 5369:2023 Table 7.4 limits.
When to order: Once per year, as required by AS 5369:2023. Also required at new autoclave installation as part of IQ/OQ validation. Applies to dedicated steam generator autoclaves with a separate feedwater supply.
If your autoclave and washer-disinfector share a water supply (single RO unit), the Combined Sterilisation Room Audit covers both Table 7.4 and Table 7.2 in one submission at a saving of $495. See the Combined Audit product.
Autoclaves require chemically pure feedwater to sterilise instruments effectively and protect equipment from corrosion. AS 5369:2023 Table 7.4 sets strict chemistry and metals limits for dedicated steam generator feedwater — stricter in several parameters than the washer-disinfector requirements.
This test covers one sample from your autoclave feedwater supply point. Your kit includes pre-labelled sample bottles, step-by-step collection instructions, and a priority courier number for same-day collection. Results are emailed as a NATA-accredited Certificate of Analysis benchmarked against all AS 5369:2023 Table 7.4 limits.
What this test covers: pH · Conductivity · Total Hardness · Chloride · Total Solids (evaporative residue) · Reactive Silica · Reactive Phosphorus · Full heavy metals screen (Cd, Pb, As, Hg + others) · Colour and appearance
All parameters reported against AS 5369:2023 Table 7.4 limits.
When to order: Once per year, as required by AS 5369:2023. Also required at new autoclave installation as part of IQ/OQ validation. Applies to dedicated steam generator autoclaves with a separate feedwater supply.
If your autoclave and washer-disinfector share a water supply (single RO unit), the Combined Sterilisation Room Audit covers both Table 7.4 and Table 7.2 in one submission at a saving of $495. See the Combined Audit product.