AS 5369:2023 requires a full annual parameter screen of your washer-disinfector final rinse water. This goes beyond the routine monthly test to include endotoxins, iron, reactive phosphates, reactive silica and a full metals screen — the complete set of parameters required under Table 7.2.
One sample from your washer-disinfector final rinse point covers this requirement. Your kit includes pre-labelled sample bottles, step-by-step collection instructions, and a priority courier number for same-day collection. Results are emailed as a NATA-accredited Certificate of Analysis benchmarked against all AS 5369:2023 Table 7.2 limits.
What this test covers: pH · Conductivity · Total Hardness · Chloride · Iron · Reactive Phosphorus · Reactive Silica · Total Viable Count (TVC) · Bacterial Endotoxins (LAL) ≤0.25 EU/mL · Full metals screen (Al, As, Cd, Ca, Cr, Cu, Fe, Pb, Mg, Hg, Ni, Se, Zn)
All parameters reported against AS 5369:2023 Table 7.2 limits.
When to order: Once per year, as required by AS 5369:2023. Also required on installation of a new washer-disinfector or RO filtration system.
If your washer-disinfector and autoclave share a water supply (single RO unit), the Combined Sterilisation Room Audit covers both Table 7.2 and Table 7.4 in one submission at a saving of $495. See the Combined Sterilisation Room Annual Audit product.
AS 5369:2023 requires a full annual parameter screen of your washer-disinfector final rinse water. This goes beyond the routine monthly test to include endotoxins, iron, reactive phosphates, reactive silica and a full metals screen — the complete set of parameters required under Table 7.2.
One sample from your washer-disinfector final rinse point covers this requirement. Your kit includes pre-labelled sample bottles, step-by-step collection instructions, and a priority courier number for same-day collection. Results are emailed as a NATA-accredited Certificate of Analysis benchmarked against all AS 5369:2023 Table 7.2 limits.
What this test covers: pH · Conductivity · Total Hardness · Chloride · Iron · Reactive Phosphorus · Reactive Silica · Total Viable Count (TVC) · Bacterial Endotoxins (LAL) ≤0.25 EU/mL · Full metals screen (Al, As, Cd, Ca, Cr, Cu, Fe, Pb, Mg, Hg, Ni, Se, Zn)
All parameters reported against AS 5369:2023 Table 7.2 limits.
When to order: Once per year, as required by AS 5369:2023. Also required on installation of a new washer-disinfector or RO filtration system.
If your washer-disinfector and autoclave share a water supply (single RO unit), the Combined Sterilisation Room Audit covers both Table 7.2 and Table 7.4 in one submission at a saving of $495. See the Combined Sterilisation Room Annual Audit product.